Thursday, May 31, 2012

new build issues

Windows 7, 8 GB of memory, Carlson 2012 build 120524, ICAD 7.1.1644.53233.p

1. Insert a block takes numerous attempts to get to work
2. Draw plan sheet (profile menu) crashes all the way to the desktop without an error submission screen
3. Concrete (Conc) Hatch doesn't work


Wednesday, May 30, 2012

I loaded the latest patch on my office computer I operated most of the day with not to many problems. As the day progressed I could sense the computer was slowing down in response time. Several of the little irritations mentioned in my earlier post occurred, but it did not cause any crashes. However, later in the day I had a quick crash, where the problem screen just closes without warning.


I am also having difficulty getting the wipeout, attached to a custom symbol, to operate correctly. I cannot get the symbol, with a wipeout, to appear in the correct order. I have opened  a job where the structure works and I have tried cut & paste the symbol without success.


Often I will open a job , a layout tab or  zoom the screen screen,  the text will all go askew. It also can happen when I insert a symbol. The problem disappears when I go the text style screen and select one item and the close.

On going Problems

I am having issues with the following
For no particular reason some commands are not being recognised and I will have an error such as
Unable to recognize command "isolate".  Please try again
I may have used the command several times previously and then without any discernible event the error comes up. Often the command will return to use by changing between screens or different jobs.

Tuesday, May 29, 2012

UNDO reliability...

Version info: Intellicad 7.1.1644.53233.P

I have often noticed UNDO does not produce the expected result.  I have a suspicion the problem might be related to the use of the ESC key to cancel commands or hit while no command is active? Here is a recent list of commands executed, I wanted to go back and change the radius used for the FILLET:
  • POLYLINE
  • FILLET
  • EXPLODE
  • ERASE
  • ERASE
  • TRIM
  • PEDIT (join)
  • PEDIT (accidentally issued - cancelled)
And now the command output copied from the command window:

Command: u
Undo: (EDITPLINE)
Command:
_U
Undo: (Unknown group)
Command:
_U
Undo: (EDITPLINE)
Command:
_U
Undo: (Unknown group)
Command:
_U
Undo: (TRIM)
Command:
_U
Undo: (ERASE)
Command:
_U
Undo: (ERASE)
Command:
_U
Undo: (EXPLODE)

The problem I have is by the time the EXPLODE was undone the polyline was gone from the drawing.

Next I tried to repeat it and this time the arc from the exploded polyline remained, could be selected and _DELETE continued to report it found one entity as I tried several time to delete it. Finally I issued a REGEN and the arc disappeared. Still the original polyline does not exist.

Okay, I have just done another test with the log file on and a script recording. I'll send them in via email to see if they are any help.

Is anyone else noticing anything odd with UNDO?

Toolbars restored oddly...

This morning when I first started Carlson the toolbars were restored in a strange manner. Each toolbar on its own line. As far as I can tell the shutdown yesterday was normal. Once I repositioned the toolbars they are again restored as expected in subsequent restarts.

Here is an image of the first restore:





and here is how they are normally:




Not sure if it is helpful and since the toolbars are restored properly again it is not an issue just a noteworthy oddity. ;-)

Edit to add version: Intellicad 7.1.1644.53233.P

Monday, May 28, 2012

Select layer from library issue...

There seems to be a wee problem with selecting a layer from the layer library when accessed while editing a field to finish code definition.

  • Draw Field to Finish
    • Edit Codes
      • Edit Field Code Definition
        • Set Main Layer (Select Layer dialog)
          • Library
When I first hit the Library button the Select Layer dialog will not dismiss. I am able to dismiss the lower dialogs and get back to a command prompt.

As I cancel I have found the layer library dialog. On another occasion when I try the same operation again immediately I see the layer library dialog in place of the Select Layer dialog.

Tried with Carlson (120524) Intellicad 7.1.1644.53233.P.

Regards,

Greg

Loading linetypes...

Intellicad Version: 7.2.1116.53013.P.VC9.x86.Alpha

Contents of test linetype file:
*DITCHL2,Ditch Left ----- L ----- L ----- L ----- L -----
A,20.,-1.,["L",ROMANS,S=1.5,R=0.0,X=-.6,Y=-.75],-1.
*DITCHR2,Ditch Right ----- R ----- R ----- R ----- R -----
A,20.,-1.,["R",ROMANS,S=1.5,R=0.0,X=-.7,Y=-.75],-1.


Attempting to load the file by hitting the Load button in the Linetype Manager dialog then browsing to the folder and selecting the file results in an error message:
Invalid file content. Please check the file and try again.

Loading the same file works when the command is run without the Linetype Manager dialog:
  1. -LINETYPE
  2. LOAD
  3. ~
  4. Browse to folder and pick file using dialog.
Response is All linetypes are loaded from the selected file. And now the linetypes are listed in the Linetype Manager.

==========================================
Intellicad Version: 7.1.1644.53233.P

I am unable to load the test file at all. The test style does exist in the drawing.

Regards,

Greg

Create linetype file...

Version: 7.2.1116.53013.P.VC9.x86.Alpha

Attempted to create a new linetype file using -LTYPE command. The file name selection dialog does not accept a file name is the file does not exist. It is not possible to create a new file this way.

Regards,

Greg

Friday, May 25, 2012

Small update is posted

We have found and fixed a crash problem introduced in Monday's update.

If you downloaded and installed build posted on Monday, please run All Programs->Carlson Software->Carlson 2012 with IntelliCAD 7.1, Check for update to fix it or simply re-apply the patch.

The corrected version is 120524, which can be verified by checking Help->About Carlson.

Sorry for the inconvenience. 

Tuesday, May 22, 2012

New PUBLIC build is posted

We have posted an update for Carlson 2012 with IntelliCAD 7.1 on the blog and on the public site today (same version is in both locations right now). 

http://update.carlsonsw.com/updates.php?product=Carlson&version=2012 

More major fixes include: 
- Zoom on locked viewports 
- Save format option is not respected 
- Improved entity highlighting on complex linetypes 
- False low memory messages 
- Regen not performed when thawing inserts 
- Entity properties leading to hang application under some conditions 
- Several more crash and deadlock scenarios are fixed 

Lots of clean up work is based on your crash submissions, please submit them if you experience crash, this really helps to clean up the problems.

Thursday, May 17, 2012

Entity properties toolbar show frozen layer...

Intellicad 7.1.1636.52167.P

Given:
  • overlaid 2d and 3d geometry with identical positions in XY plane
  • 2d and 3d geometry on different layers
  • the 3d geometry is "on top" from an entity selection perspective
  • the layer with the 3d geometry is frozen
  • neither 2d or 3d layer are current
  • use mouse to select an entity a 2d entity
For me, the layer displayed on the entity properties toolbar is the frozen 3d layer while the correct layer is displayed in the properties panel.


Toolbar icon...

Intellicad 7.2.1116.53013.P.VC9.x86.Alpha

Once a pressed-state or grayed-state variable has been set it seems they cannot be deleted. The values can be changed but not removed.

If a toolbar button is in it's grayed-state it cannot be selected to customize.


Wednesday, May 16, 2012

Extract Archive File

When I attempt to extract an archived zip file I get the following error
Error -1995: failed to extract atchive
Check that folder Wed May 16 17:18:42 2012 has write permissions

I can extract the files without a problem outside of Carlson.

I am still getting incorrect folders created in my Drawing Explorer. I can remove them using change directory, then after some time more will have been created

Thursday, May 3, 2012

Solution to mouse stickiness

Here is a suggestion our support specialist Brian Harris shared with me and I think it makes sense: Currently IntelliCAD has a selection preview (entity under the cursor highlight) turned on most of the time. Unfortunately this increases the drag (stickiness) of the mouse. Brian suggested changing current default for system variable SELECTIONPREVIEW from 3 to 2, which means highlight in the command, but not while you are just at the command line. So - type SELECTIONPREVIEW, hit Enter and set it to 2. Of course if you want it off all together - just set it to 0. Hope this helps, Leonid

Wednesday, May 2, 2012

Point Name Length bug

I had created some points using screen pick and automatic numbering, and had a rather long alphanumeric point name (9 characters). I found that the only points that were saved to my coordinate file were number 1-9.
I didn't get any error messages, the rest just didn't save.
I tried to update the crd file from drawing, and got an error for each point.
I then deleted all the points that didn't save and went back to Draw-Locate Points > Screen Pick, and when I tried to set the Starting Point Number, I couldn't enter the last digit.
I believe that my points were not saved because the alphanumeric code I used exceeded the space allowed for the point name.
I think that the allowed character limit should be greater than 9, especially using alphanumeric numbering, and I certainly believe that there should have been some error pop-up to warn me that if I exceeded the allowed character space that the points would not be saved in my crd file.

Tuesday, May 1, 2012

anyone having trouble with tangent line from circle.
such as line stays on same side even though I switch Left/Right using the select entities